Siller 30 vacuum elevator

TECHNICAL SPECIFICATIONS
General
• External cylinder diameter: 750mm
• Rated load: 159 kg (one passenger)
• Speed: 0.15 m/s
• No pit required. The lowest-level floor must be completely level
as the elevator rests on the existing floor
• No hoistway required
• Minimum overhead clearance:
o Standard head unit: 2700 mm
o Split unit: 2450 mm
• Opening required for installation through floors and
ceilings: 810mm
Mechanical requirements
• 220 V, 60/50 Hz, 25amp single-phase power supply
• 3 turbine motors located in the pump, using a total of 3kW
Cabin
• Entrance opening width: 508 mm
• Internal cabin height: 2007mm
• Internal cabin diameter:
o Between columns: 560 mm
o Without columns: 640 mm
• Automatic LED lighting and cabin fan

• Door openings: same-side (in-line) only
o Viewed from inside the cabin, all doors are hinged at the upper left and
swing to the left
• Door height: 1970 mm
• Height to top of door closer: 2020 mm
o Each specified landing level includes only one door
• 24 Volt electrical circuits, with all controls in the cabin
• Push-button call controls with precise leveling at each landing
• Telephone

Safety
• Automatic descent to ground level at a safe speed in the
event of a power failure.
• Mechanical emergency brakes engage within 5cm of free fall in the
event of vacuum loss or catastrophic failure.
• Electromechanical interlocks at each landing.
• Alarm
• Warranty: 24-month limited warranty from installation
• Machinery Directive 2006/42/EC
• CE marking

Categories