sillersillersillersillersiller

Vacuum Elevator Siller 30

TECHNICAL SPECIFICATIONS
General
• External cylinder diameter: 750mm
• Rated Load: 159 kg (Single passenger)
• Speed: 0.15 m/s
• No pit required. Bottom level floor must be 100% level
as elevator rests on existing floor
• No hoistway required
• Minimum overhead clearance:
o Standard Head Unit: 2700 mm
o Split Unit: 2450 mm
• Penetration required to install through floors and
ceilings: 810mm
Mechanical Requirements
• 220 V, 60/50 Hz, 25amp single phase power supply
• 3 turbine motors located in pump using a total of 3kW
Cabin
• Entrance width opening: 508 mm
• Internal cabin height: 2007mm
• Internal cabin diameter:
o Between columns: 560 mm
o Without columns: 640 mm
• Automatic LED lighting and cabin fan

• Door openings: same side (in-line) only
o All doors are hinged on top left, with door swing to the left,
from inside the cabin
• Door Height: 1970 mm
• Height to top of Door Closer : 2020 mm
o Each landing level specified will include only one door
• 24 Volt electrical circuits with all controls in cabin
• Push button call controls with precise leveling at each landing
• Telephone

Safety
• Automatic descent to ground level at safety speed in the
event of a power failure.
• Mechanical emergency brakes within 5cm of freefall in
vacuum loss or catastrophic failure.
• Electromechanical interlocks at each landing.
• Alarm
• Warranty: 24 month limited warranty from installation
• Machinery Directive 2006/42/EC